Digital Colorimeter

Leading Manufacturers and Wholesaler of Hans 251 Digital Colorimeter, Hans 253 Digital Colorimeter, HANS 291 Digital Colorimeter, HANS 293 Digital Colorimeter, HANS 391 Digital Colorimeter, HANS 393 Digital Colorimeter and KANAD 35 Mini Analyzer from Pune.

Business Type Manufacturer, Supplier
Five Wavelengths 450, 505, 530, 580, 630
Models Hans 251
Reading Precision Upto Two Digit
Mode Absorbance
Light Source Led Life Long Light Source
Methods Absorbance, End Point
Reagent Volume 0.250ml in Semi Micro Cuvette, 0.500ml in Micro Square Cuvette 1ml in Round Glass Cuvette
Calibration Auto Calibration with Known Standard or Artificial Standard
Photometric Range 0.000 -3.500abs
Display Lcd with Blue White Backlight, Alphanumeric
Keyboard 16 Keys,0-9nos, with Haemoglobin(hb), Calibration (cal), Absorbace(abs), Ent Key
Power 5a, 3 Pic, 230v and Battery Box with 8 a Batterys
Download View

Click to view more

Preferred Buyer From

Location Anywhere in India

Yes! I am interested


Business Type Manufacturer, Supplier
Five Wavelengths for testing suggested at 450nm, 505nm, 530nm, 580nm, 630 nm.
Reading Precision Upto Two Digit
Mode Standard, Factor, Absorbance
Model Hans 253
Light Source Led Life Long Light Source.
Methods Absorbance, End Point
Reagent Volume 0.250ml in Semi Micro Cuvette, 0.500ml in Micro Square Cuvette 1ml in Round Glass Cuvette
Calibration Auto Calibration with Known Standard or Artificial Standard
Photometric Range 0.000 -3.500abs
Display Lcd with Blue White Backlight, Alphanumeric
Keyboard 16 Keys,0-9nos, with Haemoglobin(hb), Calibration (cal), Absorbace(abs), Ent Key
Power 5a, 3 Pic, 230v and Battery Box with 8 a Batterys

Click to view more

Preferred Buyer From

Location Anywhere in India

Yes! I am interested


Business Type Manufacturer, Supplier
Nine Wavelengths for Testing Suggested At 405nm,430nm,465nm,505nm,530nm, 565nm,585nm,630nm,700nm
Reading Precision Upto Two Digit
Mode Absorbance
Model HANS 291
Light Source Led Life Long Light Source
Methods Absorbance, End Point
Reagent Volume 0.250ml in Semi Micro Cuvette, 0.500ml in Micro Square Cuvette 1ml in Round Glass Cuvette
Calibration Auto Calibration with Known Standard or Artificial Standard
Photometric Range 0.000 -3.500abs
Display Lcd with Blue White Backlight, Alphanumeric
Keyboard 16 Keys,0-9nos, with Haemoglobin(hb), Calibration (cal), Absorbace(abs), Ent Key
Power 5a, 3 Pic, 230v and Battery Box with 8 a Batterys

Click to view more

Preferred Buyer From

Location Anywhere in India

Yes! I am interested


Business Type Manufacturer, Supplier
Nine Wavelengths for testing suggested at 405nm,430nm,465nm,505nm,530nm, 565nm,585nm,630nm,700nm
Reading Precision Upto Two Digit
Mode Standard, Factor, Absorbance
Model HANS 293
Light Source Led Life Long Light Source
Methods Absorbance, End Point
Reagent Volume 0.250ml in Semi Micro Cuvette, 0.500ml in Micro Square Cuvette 1ml in Round Glass Cuvette
Calibration Auto Calibration with Known Standard or Artificial Standard
Photometric Range 0.000 -3.500abs
Display Lcd with Blue White Backlight, Alphanumeric
Keyboard 16 Keys,0-9Nos, with Haemoglobin(Hb), Calibration (CAL), Absorbace(ABS), ENT KEY
Power 5a, 3 Pic, 230v and Battery Box with 8 a Batterys

Click to view more

Preferred Buyer From

Location Anywhere in India

Yes! I am interested


Business Type Manufacturer, Supplier
Nine Wavelengths for testing suggested at 405nm,430nm,465nm,505nm,530nm, 565nm,585nm,630nm,700nm
Reading Precision Upto Three Digit
Mode Absorbance
Model No. HANS 391
Light Source Led Life Long Light Source
Methods Absorbance, End Point
Reagent Volume 0.250ml in Semi Micro Cuvette, 0.500ml in Micro Square Cuvette 1ml in Round Glass Cuvette
Calibration Auto Calibration with Known Standard or Artificial Standard
Photometric Range 0.000 -3.500abs
Display LCD with Blue White Backlight, Alphanumeric
Keyboard 16 Keys,0-9nos, with Haemoglobin(hb), Calibration (cal), Absorbace(abs), Ent Key
Power 5a, 3 Pic, 230v and Battery Box with 8 a Batterys

Click to view more

Preferred Buyer From

Location Anywhere in India

Yes! I am interested


Business Type Manufacturer, Supplier
Country of Origin India
Nine Wavelengths for testing suggested at 405nm,430nm,465nm,505nm,530nm, 565nm,585nm,630nm,700nm
Reading Precision upto Three digit
Mode Standard, Factor, Absorbance
Model Hans 393
Light Source Led Life Long Light Source
Methods Absorbance, End Point
Reagent Volume 0.250ml in Semi Micro Cuvette, 0.500ml in Micro Square Cuvette 1ml in Round Glass Cuvette
Calibration Auto Calibration with Known Standard or Artificial Standard
Photometric Range 0.000 -3.500ABS
Display Lcd with Blue White Backlight, Alphanumeric
Keyboard 16 Keys,0-9nos, with Haemoglobin(hb), Calibration (cal), Absorbace(abs), Ent Key
Power 5a, 3 Pic, 230v and Battery Box with 8 a Batterys

Click to view more

Preferred Buyer From

Location Anywhere in India

Yes! I am interested


Business Type Manufacturer, Supplier
Country of Origin India
Measuring Methods Fixed Time, End Point
Memory Storage for 35 User Defined Programs
Detector Solid State Silicon Photo Diode with Enhanced Uv Sensitivity
Self Testing Automatic Self Testing of Entire Optical System for all Wavelengths At Start Up.
Display 20 Char, 4 Lines, Blue, Alphanumeric with White Backlight.
Dimensions L: 210mm X W: 165mm X H: 95mm Appx
Weight 900 Gm Appx
Download View

Click to view more

Preferred Buyer From

Location Anywhere in India
  • 9 Wavelengths for tests suggested at:  405nm, 430nm, 465nm, 505nm, 545nm, 565nm, 585nm, 630nm, 700nm.
  • 35 User defined Programs.
  • Open System: Any reagent kit can be used, Very Easy to Program & run test.
  • All Tests for: End Point, Fixed Time, with Standard/Factor & Electrolytes
  • All types of cuvettes: Round (1ml), Square(0.500ml), Semi-Micro Cuvettes (0.250ml)
Read More...


Yes! I am interested



Looking for Product Name ?

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us